The Standard of Float Tank Gauge FT1000 and FP1000

Two different types are available.
FT-1000
The most popular float tank gauge. The float is normally guided by guide wires. The liquid level in tanks are indicated by two pointers or by digital counter. Widely applicable from normal cone roof tanks to high pressure spherical tanks. Different types of transmitters are additionally available.
 
FP-1000
Pipe sealed type with doughnut float! The liquid in tanks is perfectly isolated by magnetic coupling construction. FP-1000 is suitable for measurement of corrosive liquids
Very small flow rate can be covered:  Min. 0 - 0.5 L/h [Water] can be measured.  
 Alarm output option available:    In addition to local indication type, alarm output version is also available.
 Compact design:   Easy installation onto instrument panel.
 Safety for high temperature and pressure: All metallic material construction covers tough applications!

 

FT-1000 FP-1000
Type Float tape type Pipe seal type
Measuring object Liquids Liquids
Liquid density 0.6 to 1.9 g/cm³ 0.6 to 1.9 g/cm³
Measuring range Min. 3m to Max. 25m Min. 3m to Max. 10m
Pressure range Max.3MPa
(Subject to different shapes due to pressure rating)
Max.2MPa
(Subject to different shapes due to pressure rating)
Temp. ranges -196 to +400°C
(Subject to different shapes due to temperature rating)
0 to +150°C
(Subject to different shapes due to temperature rating)
Materials
Float: SUS304(Opt. SUS316,SUS316L)
Measuring tape: SUS316
Guide wire: SUS304(Opt. SUS316,FEP covered)
Indicator: ADC12(Opt. SCS13, SCS14)
Float: SUS304(Opt. SUS316,SUS316L)
Measuring tape: SUS316
Guide wire: SUS304(Opt. SUS316,SUS316L, PVC)
Indicator: ADC12(Opt. SCS13, SCS14)
Process connection Tank top Tank top
Indication accuracy Std. ±3mm Std. ±10mm
The above data have been data by our test equipment(Max. 3m) under the conditions, dia.400Float,no transmitter, water, normal temperature, atmospheric pressure.The above-mentioned accuracy may not be obtained, depending on the diameter of float,installation conditions, and density of liquid.
Adaptive functions
Alarm transmitters: Output accuracy ±1%F.S., Max. 6 alarm point, Weather proof, Flame proof or Intrinsically safe
Electric transmitters: Output DC4 - 20mA, Output accuracy ±1%F.S., Weather proof, Flame proof or Intrinsically safe
Pneumatic transmitters: Output 20 - 100kPa, Output accuracy ±1%F.S.
Digital transmitters: Accuracy ±1mm, Additinal data of liquid temp, Alarm status etc, Weather proof, Flame proof or Intrinsically safe