Measuring fluid |
Gases
Liquids |
Measuring range |
Air |
Min. 80 to 800 mL/min(nor)
Max. 6 to 60 L/min(nor) |
Water |
Min. 5 to 50 mL/min
Max. 0.2 to 2 L/min |
・ When selecting a flow range, refer to "Index & Quick Reference for P Series Purgemeters" (TG-S0001).
・ When selecting a flow range,refer to the standard flow rate table. |
Range ability |
10 : 1 |
Indication accuracy |
±3% F.S. |
Fluid pressure |
Max. 1MPa(Max. 0.5MPa for PVC) |
Fluid temperature |
Max. 120℃(Depends on the gasket material)
(Max. 60℃ for PVC) |
Material |
Wetted part |
SCS14/SUS304, SCS14/SUS316, PVC |
Tapered tube |
Heat-resistant glass |
Gasket |
Nitrile rubber (NBR)(Max. 80℃)
Chloroprene rubber (CR) (Max. 80ºC)
Fluoro rubber (Max. 120ºC)
PTFE(Max. 120℃) not applicable to PVC body
・The maximum fluid temperature for each gasket material may vary depending on usage and ambient conditions. |
Mounting plate |
SPCC, SUS304 |
Cover |
Acryl, SPCC, SUS304 |
Process Connection |
Rc : 1/4"(Standard), 1/8", 3/8", 1/2"
NPT : 1/8", 1/4", 3/8", 1/2"
Flange : 10A, 15A, 20A, 25A |
Mounting |
Lock nut mount on panel front (Standard)
Flange connection
With stand |
Mass |
approx. 0.9kg |