Measuring
object |
Measurable materials: Liquids and Slurries
Measuring method: FMCW(Frequency Modulated Continuous Wave)
Measurable variable: Level, Distance,and Volume |
Measuring
range |
0.5 to 40m (Depending on the measuring conditrion) |
Temperature of
process
connection |
-40 to +200°C: Horn antenna (Standard type)
-40 to +150°C: Drop antenna (PTFE) (Standard type)
-40 to +100°C: Horn antenna (PP) (Standard type)
(Explosionproof type: Refer to EXPLOSIONPROOF SPECIFICATIONS) |
Operating
pressure |
0kPa (abs) to 4MPa: Horn antenna (subject to flange rating)
0kPa (abs) to 1.6MPa: Drop antenna (subject to flange rating) |
Dielectric constant |
1.5 or more (Depending on the measuring condition) |
Antenna type |
DN40 / 50 Horn antenna (Thread connection)
DN40 / 50 Horn antenna (Flange connection)
DN80 Horn antenna (Flange connection)
DN100 Horn antenna (Flange connection)
Drop antenna (Flange connection)
Drop antenna, with flange plate (Flange connection) |
Display |
9 lines 160 × 160 pixels in 8-step grey scale
4 buttons (Right shift key, Enter key, Up key and Down key)
Language: English or Japanese |
Output |
Output1: DC4 to 20mA (HART) |
Accuracy
(Based on
criteria condition) |
Liquid measurement: |
|
±3mm/R.D. (Less than 10m),
±0.03%/R.D. (10m or more) |
|
Power supply |
Rated voltage: 24V DC
Voltage range: 20 to 36V DC (Exd)
Voltage range: 14 to 30V DC (Non-Ex, Exia) |
Material |
Housing:Aluminum alloy |
Process connection: |
Stainless steel SS316L (Option: Hasteloy®C-22) |
Gas contact part: |
Stainless steel SS316L (Option: Hasteloy®C-22) |
Seal:FKM(-40 to 200°C)(Option: Kalrez®6375(-20 to 200°C)) |
|
Connection |
Thread: |
G1 1/2 Male / 1 1/2" NPT Male |
Flange: |
1 1/2", 2", 3", 4", 6", 8", ASME 150lbs, 300lbs / 40A, 50A, 80A, 100A JIS 10K |
|
Protection class |
General type: |
IP67 (JIS C0920, Equivalent to NEMA6) |
Explosionproof: ATEX |
EEx ia IIC T3…T6,
EEx d [ia] IIC T3…T6 |
|